ARC FLASH RISK MANAGEMENT UNDER NR-10: PROPOSAL FOR A TECHNICAL PROCEDURE TO ASSESS THE COMPLIANCE OF ELECTRICAL INSTALLATIONS WITH MTE ORDINANCE No. 737/2026
DOI:
https://doi.org/10.63330/sasciencesv6n2-326Keywords:
Arc flash, Compliance, Electrical installations, Incident energy, NR-10Abstract
Arc flash risk represents a relevant aspect of safety management in industrial electrical installations, particularly in light of the changes introduced by MTE Ordinance No. 737/2026, which approved the revised version of Regulatory Standard No. 10 (NR-10). In this context, this study aims to analyze the requirements related to arc flash risk established by the aforementioned Ordinance and to propose a technical procedure for assessing the compliance of electrical installations with the revised NR-10, using incident energy analysis as support for decision-making. The research is characterized as applied, with a qualitative-quantitative approach and exploratory and descriptive objectives, conducted through bibliographic and documentary research and practical application of the proposed procedure. Initially, the NR-10 changes related to arc flash will be mapped, and the technical and documentary requirements necessary for compliance assessment will be identified. Subsequently, a procedure will be structured covering the collection and validation of installation data, verification of the applicability of the incident energy study, assessment of requirements, and identification of necessary corrective actions. At technically applicable points with traceable data, the criteria established by ABNT NBR 17227:2025 and the methods provided by IEEE Std 1584-2018 will be used to determine arcing current, incident energy, and arc-flash boundary. The application of the procedure will enable the assessment of aspects related to collective protection measures, documentation, labeling, work procedures, and the specification of personal protective equipment. As a result, the study is expected to provide a structured and replicable technical procedure capable of supporting professionals and organizations in identifying compliance gaps, prioritizing corrective actions, and managing arc flash risk in accordance with the requirements of the revised NR-10.
Downloads
References
AMMERMAN, R. F.; GAMMON, T.; SEN, P. K.; NELSON, J. P. Comparative study of arc modeling and arc flash incident energy exposures. IEEE Transactions on Industry Applications, v. 43, n. 1, p. 236–245, 2007.
ASSOCIAÇÃO BRASILEIRA DE NORMAS TÉCNICAS. (2025). ABNT NBR 17227: 2025: Segurança elétrica — Gerenciamento dos riscos relacionados à energia incidente de arco elétrico.
BACIN, P. O., FAVA, M. F., LONDERO, R. P., MARCHESAN, T. B., BENDER, V. C., BELTRAME, R. C., BERNARDON, D. P., FALCÃO, C. E. G., SIMÕES, C. A., & SANTOS, G. J. G. (2025). Incident energy determination of three-phase arc flash using magnetohydrodynamics simulations: A case study for horizontal electrodes in open-air configurations. High Voltage. https://doi.org/10.1049/hve2.70009
BACIN, P. O., et al. (2022). Contribuição ao desenvolvimento de um laboratório de arco elétrico controlado para medição da energia incidente. Simpósio Brasileiro de Sistemas Elétricos – SBSE, 2(1). https://doi.org/10.20906/sbse.v2i1.2983
BRASIL. Ministério do Trabalho e Emprego. (2026). Portaria MTE nº 737, de 29 de maio de 2026: Aprova a nova redação da Norma Regulamentadora nº 10 (NR-10) — Segurança em instalações e serviços em eletricidade.
BUGARIS, R. M., & DOAN, D. R. (2014). Arc-flash incident energy variations: A study of low-voltage motor control center unit configurations and incident energy exposure. IEEE Industry Applications Magazine, 20(3), 40–45. https://doi.org/10.1109/MIAS.2013.2288386
CADICK, J., CAPELLI-SCHELLPFEFFER, M., NEITZEL, D. K., & WINFIELD, A. (2012). Electrical safety handbook (4th ed.). McGraw-Hill.
CELLARD, A. (2008). A análise documental. In J. Poupart et al., A pesquisa qualitativa: Enfoques epistemológicos e metodológicos. Vozes.
CRESWELL, J. W., & CRESWELL, J. D. (2018). Research design: Qualitative, quantitative, and mixed methods approaches (5th ed.). SAGE Publications.
DAS, J. C. (2012). Arc flash hazard analysis and mitigation. Wiley-IEEE Press. https://doi.org/10.1002/9781118402498
DOAN, D. R. (2010). Arc flash calculations for exposures to DC systems. IEEE Transactions on Industry Applications, 46(6), 2299–2302. https://doi.org/10.1109/TIA.2010.2070470
DREWISKE, G. W. (2014). Engineering incident energy analysis and remediation project in a Midwestern pulp and paper mill. IEEE Transactions on Industry Applications, 50(1), 104–112. https://doi.org/10.1109/TIA.2013.2288232
GIL, A. C. (2022). Como elaborar projetos de pesquisa (7th ed.). Atlas.
HOAGLAND, H., GOLOVKOV, M., MAURICE, C., & CLARK, P. (2014). Clothing in arc flash: Four types of arc exposure and the effect of moisture on garment appearance after an arc event. IEEE Transactions on Industry Applications, 50.
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS. (2018). IEEE Std 1584-2018: IEEE guide for performing arc-flash hazard calculations. IEEE.
LEE, R. H. The other electrical hazard: electric arc blast burns. IEEE Transactions on Industry Applications, v. IA-18, n. 3, p. 246–251, 1982.
NEITZEL, D. K., CAPELLI-SCHELLPFEFFER, M., & WINFIELD, A. (2019). Electrical safety handbook (5th ed.). McGraw-Hill Education.
SARA IJI, R.; HAMDAN, M. O.; HARB, A. Illuminance degradation of LED streetlighting luminaires in a hot environment. LEUKOS, v. 9, n. 3, p. 201–216, 2013. DOI: 10.1582/LEUKOS.2013.09.03.004.
STOKES, A. D.; OPPENLANDER, W. T. Electric arcs in open air. Journal of Physics D: Applied Physics, v. 24, n. 1, p. 26–35, 1991.
VALDES, M., HANSEN, S., & SUTHERLAND, P. E. (2010). Optimizing circuit breaker instantaneous trip settings for selectivity and arc flash performance simultaneously. In 2010 IEEE IAS Electrical Safety Workshop. IEEE. https://doi.org/10.1109/ESW.2010.6164467
Downloads
Published
How to Cite
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Autores concordam com os seguintes termos:
a) Os autores mantêm os direitos autorais e concedem à revista o direito de primeira publicação, com o trabalho simultaneamente licenciado sob a LicençaAttribution-NonCommercial-ShareAlike 4.0 International, que permite o compartilhamento do trabalho com reconhecimento da autoria e publicação inicial na Revista SAS. A licença permite o uso, a distribuição e a reprodução irrestrita, em qualquer meio, desde que devidamente citada a fonte. Essa licença permite também que outros remixem, adaptem e criem a partir do seu trabalho para fins não comerciais, desde que atribuam a você o devido crédito e que licenciem as novas criações sob termos idênticos.
b) Não cabe aos autores compensação financeira a qualquer título, por artigos ou resenhas publicados na South American Sciences.
c) Os conceitos expressos nos artigos publicados na South American Sciences são de inteira responsabilidade de seus autores.